Rees Minikevlar 102.00.042
Cores
2 coaxials 75 ohm
1 screened quad (7 x 0.2mm) <.008”>
2 groups of 7 (each 7 x 0.2mm)
1 group of 5 (each 7 x 0.2mm)
3 singles (each 7 x 0.2mm)
3 earth returns (each 16 x 0.2mm)
REES Cables & Connectors
IST R90 Series Cables and Connectors are
designed for use with all of the R90 Series nuclear cameras
and have been specifically developed for nuclear applications
underwater or in air.
All the IST R90 Series cameras have a very high radiation tol-
erance which is partly achieved by their dual unit construction
with the majority of the camera electronics being contained in
a separate camera control unit (CCU) outside the active area.
This design approach reduces radiation damage, while also
ensuring easy service access. The CCU’s are linked to their
associated cameras by single composite camera cables - with
matching connectors - which provide all the necessary power,
control and signal functions.
Imaging & Sensing Technology Corporation
Features
Air and underwater
appplications
Radiation tolerant
Wide range
Specifically developed
for nuclear operations
Site reterminable
connectors
Field proven design
Mechanical
Diameter ...............................................11.30mm <.44”> (±0.38mm)
(<.015”>
Installation bend radius ........................82mm min (3.2”)
Continuous flexing bend radius.............165mm min (6.5”)
Weight in air .........................................170g/m (.44 lb/yd)
Break strength .......................................324kg (714 lb)
Operating temp.range ...........................-20° to 70°C (-4°F to 158°F)
Total radiation dose .............................106 Gy (108 rads)
Electrical
75 ohm coaxial:
Characteristic impedance .....................75 ± 2 ohms
Attenuation ...........................................5.7 dB per 100m (328’) at 10 MHz
XLPE Insulated Cores:
dc resistance .........................................8.8 ohms per 100m (328’) nominal
Earth returns:
dc resistance .........................................4.0 ohms per 100m (328’) nominal
31 core camera cable with
kevlar strength member,
XLPE cores, and polyure-
thane elastomer jacket.
Page view 0
1 2 3 4

Summary of Contents

Page 1 - Cables & Connectors

Rees Minikevlar 102.00.042Cores2 coaxials 75 ohm1 screened quad (7 x 0.2mm) <.008”>2 groups of 7 (each 7 x 0.2mm)1 group of 5 (each 7 x 0.2mm)3

Page 2

Specifications and PerformanceTV36 102.00.019Cores3 coaxials 75 ohm1 group of 14 (each 7 x 0.16mm) <.006”>1 screened group of 7 (each 7 x 0.16

Page 3

REES Cables & ConnectorsStandard Cables Separation (m) Cable Camera to CCU Operation NotesTV36 200 Lighting current 6A max102.00.019 Full

Page 4 - Camera/CCU Mating Connectors

w w w . i s t i m a g i n g . c o mImaging and Sensing Technology Corporation1105 IST reserves the right to amend or change the information on this sh

Comments to this Manuals

No comments